Syringeless and Syringe Filters
- (8)
- (12)
- (279)
- (9)
- (73)
- (1)
- (376)
- (1)
- (14)
- (12)
- (1)
- (3)
- (20)
- (1)
- (14)
- (1)
- (2)
- (5)
- (2)
- (1)
- (3)
- (3)
- (20)
- (3)
- (9)
- (2)
- (5)
- (63)
- (2)
- (17)
- (1)
- (4)
- (37)
- (1)
- (12)
- (2)
- (127)
- (86)
- (2)
- (92)
- (1)
- (42)
- (53)
- (96)
- (20)
- (4)
- (2)
- (1)
- (8)
- (4)
- (3)
- (7)
- (57)
- (26)
- (566)
- (125)
- (6)
- (472)
- (16)
- (31)
- (13)
- (22)
- (187)
Filtered Search Results
Cytiva Whatman™ 25 mm Puradisc RC Syringe Filters, 0.2 μm
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Syringe filter with RC membrane, hydrophilic and chemically resistant for use with both aqueous and aggressive organic solvents.
| Pore Size | 0.2 μm |
|---|---|
| Type | Syringe Filter |
| Outlet Style | Male Slip Luer |
| Diameter (Metric) | 25 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Polypropylene |
| Sample Volume | Up to 100 mL |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Dimensions (L x W) | 22.9 x 28.4 mm |
| Membrane Type | RC Membrane |
| Max. Pressure | 5.2 bar (75 psi) |
| Filtration Area | 4.2 cm2 |
DWK Life Sciences DURAN™ 5.8 mm Connector and 0.2 μm Syringe Disk Filter
The DURAN™ 5.8 mm Connector and 0.2 μm Syringe Disk Filter is an accessory for the DURAN™ Screw Cap GL 45 with 2-hose connector. It combines a non-sterile 0.2 μm syringe filter with a female Luer Slip to 5.8 mm male connector and O-ring seal.
MilliporeSigma™ Millex™ Syringe Filter, Glass Fiber, 25mm dia.
25 mm diameter, Millex-AP glass fiber membrane, hydrophilic.
Choice™ Nylon Syringe Filters
Use Thermo Scientific™ Choice™ Nylon Syringe Filters as the economic option for most general laboratory filtration, and for filtration of most HPLC samples.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | Nylon |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
Cytiva Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa
Processes sample loads in one-third the time. Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa provide a faster and easier way to remove particulates from samples being prepared for HPLC and UHPLC analysis.
| For Use With (Application) | Routine HPLC/UHPLC analysis; Composite assays; Content uniformity; Protein precipitation; Solubility testing; Dissolution testing; Sample filtration; Standard robotics on HPLC instruments with sensitive needles, allowing for higher throughput; Light sen |
|---|
Cytiva Whatman™ Autovial™ Syringeless Filters: 12mL Capacity, Nonsterile
Faster sample handling, up to 12mL in volume
| Type | Syringeless Filter |
|---|---|
| Diameter (Metric) | 25 mm |
| Volume (Metric) | ≤12 mL |
| Sterility | Non-sterile |
MilliporeSigma™ Millex™ Filters: Female Luer-Lok™ Inlet, Male Luer Slip Outlet
Protect vacuum sources from contamination and moisture damage with Millex™ Syringe Filters with Female Luer-Lok™ Inlet and Male Luer Slip Outlet.
| Pore Size | 0.2 μm |
|---|---|
| Disposable | Single-use |
| For Use With (Equipment) | Tubing |
| Diameter (Metric) | 25 mm |
| Housing Material | PTFE |
| Material (Membrane) | PTFE |
| Volume (Metric) | 100 mL |
| Quantity | 50/Pk. |
| Filter Type | Air Syringe Filter |
| Autoclavable | Autoclavable |
MilliporeSigma™ Millex™ Syringe Filter, Hydrophilic PTFE, 0.2 μm
Millex™ Syringe Filters for removing particulates, reducing signal-to-noise ratios and maintaining flat baselines.
Cytiva Whatman™ Puradisc 25mm PTFE Syringe Filters
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Contains hydrophobic membrane that is chemically stable and inert. Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples.
| Type | Syringe Filter |
|---|---|
| Dimensions (L x W x H) | 22.9 x 28.4 mm |
| Outlet Style | Male Luer |
| Diameter (Metric) | 25 mm |
| Inlet Style | Female Luer Lock |
| Material (Membrane) | PTFE |
| Volume (Metric) | Up to 100 mL |
| Pressure Rating | 5.2 bar (75 psi) |
| Material | PTFE |
| For Use With (Application) | For HPLC, TLC, and GC sample clarification; HPLC solvent filtration |
| Sterility | Non-sterile |
| Filtration Area | 4.2 cm2 |
Sartorius Minisart™ SRP Syringe Filters: Nonsterile, Small Spike Outlet
Ready-to-use units for simple, rapid and reliable ultracleaning of small volume samples for the HPLC or GC analysis
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Outlet Style | Small spike |
| For Use With (Equipment) | Syringe |
| Diameter (Metric) | 15 mm |
| Volume (Metric) | 15 mL |
| Sample Volume | 0.5 to 15 mL |
| Material | PTFE |
| Filter Type | Syringe Filter |
| For Use With (Application) | For simple, rapid and reliable ultracleaning of small volume samples for the HPLC or GC analysis. |
| Sterility | Non-sterile |
Cytiva Whatman™ ReZist Air Venting Filter, 50mm, PTFE, 0.2μm
ReZist in-line filters are lightweight air venting units suitable for protective vents, in-line filtration, and isolation applications when working with chemically harsh solvents.
| Pore Size | 0.2 μm |
|---|---|
| Type | ReZist Syringe Filter |
| Outlet Style | Tubing nozzle (6-10mm I.D. hose) |
| Diameter (Metric) | 50 mm |
| Inlet Style | Tubing nozzle (6-10mm I.D. hose) |
| Housing Material | Polypropylene (PP) |
| Material (Membrane) | PTFE |
| Volume (Metric) | ≤100 mL |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Suitable for protective vents, in-line filtration and isolation applications |
| Prefilter | Polypropylene (PP) |
| Sterility | Non-sterile |
| Filtration Area | 20.4 cm2 |
Basix™ Syringe Filters, PES, Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PES, Sterile offers high sample throughput.
| Diameter (Metric) | 25 mm |
|---|---|
| Housing Material | Acrylic |
| Material (Membrane) | PES |
| Sterility | Sterile |
Basix™ Syringe Filters, Nylon, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | Nylon |
| Sterility | Non-sterile |
Fisherbrand™ Syringe Filters - Sterile
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Hold up Volume (After Air Purge) | Low |
Basix™ Syringe Filters, PTFE, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PTFE, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | PTFE (Hydrophobic) |
| Sterility | Non-sterile |