Filters and Filtration
Filtered Search Results
Cytiva Grade 740E Filter Discs
Meets FDA/WHO antibiotic-assay control disc standards. Whatman™ Grade 740E Filter Discs are thick, highly absorbent paper discs made of high-purity cotton linter for use in antibiotic-assay procedures.
Fisherbrand™ Qualitative Grade Plain Filter Paper Circles - P8 Grade
Ideal for clarifying and removing particles of 20μm and larger, and in applications that do not require a low-ash or ashless paper.
| Flow Rate | Fast: 160mL/min. |
|---|---|
| Particle Retention | 20 to 25 μm |
| Format | Disc |
| Quantity | 100/Pk. |
| Grade | P8 |
| Material | Cellulose |
| Porosity | Coarse |
| Filtration Speed | 55 sec. |
| For Use With (Application) | Suitable for coarse and gelatinous precipitates. Retains Fe(OH)3, Al(OH)3, metallic sulfides, iron ores. For clarifying solutions, oils. For zinc analysis (Fe ppt removal). Size 19cm (09-804) widely used for sugar analysis. |
Fisherbrand™ Qualitative Grade Plain Filter Paper Circles - P5 Grade
Ideal for clarifying and removing particles of 1μm and larger, and in applications that do not require a low-ash or ashless paper
| Flow Rate | Slow: 60mL/min. |
|---|---|
| Particle Retention | 5 to 10 μm |
| Format | Disc |
| Grade | P5 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 230 sec. |
| For Use With (Application) | General lab uses: clinical and spot testing, clarifying pharmaceuticals |
Fisherbrand™ Qualitative Grade Plain Filter Paper Circles and Sheets - P4 Grade
Ideal for clarifying and removing particles of 1μm and larger, and in applications that do not require a low-ash or ashless paper
| Flow Rate | Slow: 25mL/min. |
|---|---|
| Particle Retention | 4 to 8 μm |
| Format | Disc |
| Grade | P4 |
| Porosity | Medium Fine |
| Filtration Speed | 730 sec. |
| For Use With (Application) | General purpose: slightly slower, more retentive than P5. Retains MgNH4PO4, silver sulfide, cadmium sulfide. In air monitors, collects particulates and chromic acid mist |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
| Thickness (Metric) | 150 μm |
|---|---|
| Pore Size | 0.45 μm |
| Disposable | Reusable |
| Flow Rate | 60 mL/min. x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Material | MCE |
| Filter Type | Membrane Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Cytiva Whatman™ Qualitative Filter Paper: Grade 2 Circles
Retains and absorbs more than Grade 1 filters, with a corresponding increase in filtration time. Whatman™ Qualitative Filter Paper: Grade 2 Circles are used for monitoring specific contaminants in the atmosphere and in soil testing.
| Thickness (Metric) | 190 μm |
|---|---|
| Flow Rate | Medium |
| Particle Retention | >8 μm |
| Format | Disc |
| Quantity | 100 Pk. |
| Grade | Grade 2 |
| Material | Cellulose |
| Porosity | Medium Fine |
| Filtration Speed | 240 sec. |
| For Use With (Application) | A standard grade filter used for monitoring specific contaminants in the atmosphere and in soil testing. |
Cytiva Whatman™ Qualitative Filter Paper: Grade 1 Circles
Covers a wide range of laboratory applications and is frequently used for clarifying liquids. Whatman™ Qualitative Filter Paper: Grade 1 Circles are widely used standard grade filter papers for routine applications with medium retention and flow rates.
| Thickness (Metric) | 180 μm |
|---|---|
| Flow Rate | 57mL/min. (water) |
| Particle Retention | >11 μm |
| Basis Weight | 87 g/m2 |
| Format | Disc |
| Airflow Rate | 13sec./100mL/sq. in. |
| Grade | Grade 1 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 150 sec. |
| For Use With (Application) | A widely used standard grade filter paper for routine applications with medium retention and flow rate. It covers a wide range of laboratory applications and is frequently used for clarifying liquids. |
Cytiva Whatman™ Quantitative Filter Paper: Grade 42 Circles
Filters and retains extremely small particles. Whatman™ Quantitative Filter Paper: Grade 42 Circles are suitable for processes that require ashing.
| Thickness (Metric) | 200 μm |
|---|---|
| Pore Size | 2.5 μm |
| Flow Rate | Slow |
| Type | Quantitative Filter Paper |
| Format | Disc |
| Airflow Rate | 96 s/100 mL/in2 |
| Quantity | 100 Pk. |
| Grade | Grade 42 |
| Material | Cotton Linters |
| Filter Type | Ashless |
| Porosity | Fine |
| Filtration Speed | 1870 sec. |
| For Use With (Application) | Designed for gravimetric analysis and the preparation of samples for instrumental analysis.For critical gravimetric analysis with the finest particle retention. |
Synthware™ Filter Tubes with Fritted Disc
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Used for filtration followed by recrystallization on opposite side of disc of air sensitive compounds
| Material | Borosilicate Glass (3.3) |
|---|
Synthware™ Filter Tubes with Fritted Disc
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Used to filter particulates from substance
| Includes | Two 2 mm glass stopcocks |
|---|
Cytiva Whatman™ Qualitative Filter Paper: Grade 4 Circles
Filters and retains coarse particles for monitoring air pollution. Whatman™ Qualitative Filter Paper: Grade 4 Circles are used when high flow rates in air pollution monitoring are required and the collection of fine particles is not critical.
| Thickness (Metric) | 210 μm |
|---|---|
| Pore Size | 20 to 25 μm |
| Flow Rate | Fast |
| Particle Retention | 25 μm |
| Format | Disc |
| Grade | Grade 4 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 37 sec. |
Cytiva Whatman™ Quantitative Filter Paper: Grade 41 Circles
Use for quantitative air pollution analysis as a paper tape for impregnation when determining gaseous compounds at high flow rates or for quantitative air pollution analysis. Whatman™ Quantitative Filter Paper: Grade 41 Circles are commonly used in preparing samples for metal analysis after nitric acid digestion.
| Thickness (Metric) | 215 μm |
|---|---|
| Pore Size | 20 μm |
| Flow Rate | Fast |
| Particle Retention | 20 μm |
| Type | Quantitative Filter Paper |
| Format | Disc |
| Quantity | 100 Pk. |
| Material | Cotton Linters |
| Porosity | Coarse |
| Filtration Speed | ASTM, 12 seconds; Herzberg, 54 seconds |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Thickness (Metric) | 260 μm |
|---|---|
| Flow Rate | 10.5 sec./100 mL |
| Particle Retention | 1.2 μm |
| Temperature (English) Max. | 932°F |
| Basis Weight | 53 g/m2 |
| Shape | Circle |
| Format | Disc |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Thickness (English) | 0.01 in. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Waterflow Rate | 105 mL/min |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/F |
| Material | Borosilicate Glass |
| For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
| Thickness (Metric) | 420 μm |
| Flow Rate | 19 sec./100mL/in.2 |
| Type | Filter for TCLP Test Use |
| Format | Disc |
| Thickness (English) | 0.016 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 41 mL/min |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade 934-AH Circles
Designed for analysis of non-filterable residue and materials that require a high loading capacity glass microfiber filter. Whatman™ Binder-Free Glass Microfiber Filters, Grade 934-AH Circles are also used in cell harvesting, liquid scintillation, and monitoring pollution.
| Particle Retention | 1.5 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade 934-AH borosilicate glass microfiber filters from GE are smooth water quality filters with high retention efficiency. Grade 934-AH filters are often used in total suspended solids analysis. |
| Filtration Time | 47 sec./100mL |
| Quantity | 100 Pack |
| Grade | Grade 934-AH |
| Material | Borosilicate Glass |
| Thickness (Metric) | 435 μm |
| Flow Rate | 3.7 sec./100mL/in.2 |
| Type | Filter for Total Suspended Solids Analysis |
| Basis Weight | 64 g/m2 |
| Format | Disc |
| Thickness (English) | 0.017 in. |
| Surface Type | Smooth |
| Waterflow Rate | 341 mL/min |