missing translation for 'onlineSavingsMsg'
Learn More

Hamilton™ PRP-1 Reversed Phase HPLC Columns, 5um Particle Size

Catalog No. 1481654
Change view
Click to view available options
Length (Metric):
50 mm
150 mm
Diameter (Metric):
4.1 mm
4.6 mm
Material:
PEEK
Stainless Steel
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Catalog No. Length (Metric) Diameter (Metric) Material
1481654 50 mm 4.1 mm Stainless Steel
1481618 150 mm 4.1 mm Stainless Steel
1481655 150 mm 4.6 mm PEEK
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Catalog No. 1481654 Supplier Hamilton™ Supplier No. HAM79443

Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

Stable alternative to C8 or C18 Columns

Wide pH Stability

  • Stability from pH 1 to 13 allows for the analysis of samples at high pH (8-13) without the possibility of column degradation or loss of efficiency. An expanded pH range also allows samples to be chromatographed while ionized.
  • Good Sample Recovery
    • Since PRP-1 is made entirely of poly(styrene-divinylbenzene), there are no silanol groups to cause sample loss, thus the recovery and quantitation of labile and reactive samples is enhanced.
  • Consistent Reproducibility
    • PRP-1 reversed phase columns are ideal for applications that require a high degree of column-to-column and batch to batch consistency (i.e., quality assurance, clinical trials). Unlike C8 or C18 columns, PRP-1 has no stationary phase coating.
  • Easy Sample Scale-up
    • Columns are available prepacked and tested in a variety of sizes, varying from analytical to semi-prep and preparative scale. Consistent packing material allows linear method scale-up.
  • Long Life (Excellent Durability)
    • PRP-1 columns are packed with a poly(styrene-divinylbenzene) material. This support is pressure stable up to 5,000psi, and cross-linked to prevent shrinkage or swelling (common in other polymeric columns). Since the support is entirely polymeric with no silica to deteriorate, column lifetime is longer for PRP-1 than silica C4, C8 or C18 columns.

    • Column internal diameters: 4.1 and 4.6mm
    • Two column materials: 316 stainless steel and PEEK
    • Analytical guard columns

    Specifications

    Column Format Analytical Column
    Diameter (Metric) 4.1 mm
    Film Thickness 5 μm
    For Use With Organic Compounds, Pharmaceuticals, Steroids, Nucleic Acids, Vitamins, Herbicides
    Length (Metric) 50 mm
    Max. Pressure 5000 psi (345 bar)
    Mobile Phase Compatibility pH 1 to 13, 0 to 100% aqueous, organic modifier
    Particle Size 5 μm
    pH 1 to 13
    Pore Size 100 Å
    Temperature 5°C to 85°C
    USP Type L21
    Stationary Phase PSDVB (Polystyrene Divinylbenzene)
    Product Line PRP-1
    Packing Material PSDVB (Polystyrene Divinylbenzene)
    Column Type Reversed Phase
    Phase Reversed Phase
    Material Stainless Steel
    Technique Reverse Phase HPLC
    Product Type Column
    Show More Show Less