UserName
Make any pH meter a dissolved oxygen meter with this dissolved oxygen/BOD probe.
Dissolved Oxygen (Concentration Range) | 0 to 14 ppm |
---|---|
For Use With (Equipment) | Dissolved Oxygen/BOD Probe |
Sensor Types | Polarographic Dissolved Oxygen Sensor |
Temperature (Metric) Operating | 15°C to 35°C |
Use this standard epoxy DO probe in the lab or the field for reliable results no matter what the environment.
Use this dissolved oxygen (DO) probe, featuring automatic temperature compensation and convenient screw-on membrane caps, in the lab or in the field.
Connections | 9-pin MiniDIN |
---|---|
Max. Overpressure | 6 bar |
Response Time | 90% of final value in 10 sec. |
Oxygen Consumption | 0.008μg/h (mg/L)-1 at 20°C |
Sensor Types | Dual Thermally Separated |
Min. Sample Flow | 10 cm/sec. |
Drift | ∼0.1%/day |
Storage Requirements | -5°C to +50°C |
Temperature (Metric) Operating | 0°C to 50°C |
Accessory for use with InLab 605 Dissolved Oxygen Electrode.
Measure dissolved oxygen levels without the difficulties of membrane replacement by using this RDOâ„¢ dissolved oxygen probe.
Type | Dissolved Oxygen Probe |
---|---|
Dissolved Oxygen (Concentration Range) | 0.00 to 20.0 mg/L |
For Use With (Equipment) | Orion Star Meter with RDO input |
Sensor Types | RDO Optical Dissolved Oxygen Sensor |
Temperature (Metric) Operating | 0°C to 50°C |
Probe Type | RDO Optical Dissolved Oxygen |
Dissolved Oxygen (Saturation Range) | 0.0 to 200% |
Accurately and conveniently conduct dissolved oxygen measurements with this BOD probe, which features an integrated stirrer.
A selection of dissolved oxygen probes suitable for all applications.
Type | Dissolved Oxygen Probe |
---|---|
Length (Metric) Cable | 1.80 m |
Length (English) Cable | 5 ft. |
Temperature (Metric) Operating | 0°C to 60°C |
For Use With (Application) | Routine pH measurement |
Probe Type | DO Sensor |
Robust and easy to use sensors. Mettler Toledo Indicating Galvanic Sensors have integrated temperature sensor. Galvanic dissolved oxygen sensor provides an easy way to measure DO.
Connections | BNC/Cinch |
---|---|
Type | Dissolved Oxygen Sensor |
For Use With (Equipment) | FG4 |
Sensor Types | Dissolved Oxygen |
Temperature (Metric) Operating | 0°C to 60°C |
For Use With (Application) | DO |
Includes | Temperature/conductivity sensor |
---|---|
Warranty | 1 Year |
For Use With (Equipment) | YSI model 556 handheld multi probe meter |
For Use With (Application) | Measures DO, temperature, conductivity |
Replace electrodes when they break, no longer hold calibration, cannot be rehydrated, or are not compatible with your sample.
Stores calibration data within the sensor, allowing probes to be placed on any ProODO instrument without re-calibration
Accuracy | ±1%mg/L |
---|---|
Warranty | 2 Years |
Temperature (Metric) Range | 10°C to 40°C |
For Use With (Equipment) | DO/temperature meter |
Certifications/Compliance | RoHS, CE, WEEE, IP65 |
For Use With (Application) | Stores calibration data within the sensor |
Probe Type | ProODO |
Temperature Resolution | 0.1°C |
Velp Scientificaâ„¢ BOD Sensor Check for use with BOD and BOD EVO Sensors.