missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ PBFI, Tetraammonium Salt, cell impermeant

Catalog No. P1265MP
Encompass
Change view
Click to view available options
Quantity:
1 mg
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Catalog No. Quantity
P1265MP 1 mg
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Catalog No. P1265MP Supplier Invitrogen™ Supplier No. P1265MP
Season of Savings
View all promotions

Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

PBFI is potassium-sensitive molecule used measure intracellular K+ fluxes in animal cells and in plant cells and vacuoles

PBFI is a potassium-sensitive molecule used measure intracellular K+ fluxes in animal cells and in plant cells and vacuoles. Although the selectivity of PBFI for K+ is less than that of calcium indicators such as fura-2, it is sufficient for the detection of physiological concentrations of K+ in the presence of other monovalent cations. The spectral response of PBFI upon ion binding permit excitation ratio measurements, and this indicator can be used with the same optical filters and equipment used for fura-2.

Fluorescent Ion Indicators Specifications:

  • Label (Ex/Em): PBFI (∼340,380/500 nm)
  • Lyophilized product may be dissolved in distilled water or aqueous buffer for use
  • Product is typically loaded into cells by diffusion from a patch pipette for correlated fluorescence imaging and electrophysiological recording

Selectivity Considerations and Cell Loading Strategies

The Kd of PBFI for K+ is strongly dependent on whether Na+ is present, with a value of 5.1 mM in the absence of Na+ and 44 mM in solutions with a combined Na+ and K+ concentration of 135 mM (which approximates physiological ionic strength). In buffers in which the Na+ is replaced by tetramethylammonium chloride, the Kd of PBFI for K+ is 11 mM; choline chloride and N-methylglucamine are two other possible replacements for Na+ in the medium. Although PBFI is only 1.5-fold more selective for K+ than for Na+, this selectivity is often sufficient because intracellular K+ concentrations are normally about 10 times higher than Na+ concentrations.

PBFI is available as both cell-impermeant acid salt (Cat. No. P1265MP) and as cell-permeant acetoxymethyl (AM) esters (Cat. No. P1267MP). The anionic acid forms can be loaded into cells using our Influx™ pinocytic cell-loading reagent (Cat. No. I14402), Chelators, Calibration Buffers, Ionophores and Cell-Loading Reagents—Section 19.8), or by microinjection, patch-pipette infusion or electroporation. For AM ester loading (Loading and Calibration of Intracellular Ion Indicators—Note 19.1), addition of the Pluronic™ F-127 (Cat. No. P3000MP), (Cat. No. P6866), (Cat. No. P6867) or PowerLoad™ (Cat. No. P10020) dispersing agents as well as relatively long incubation times—up to four hours—are typically necessary.

Find Fluorescent Indicators for Na+ and K+

We offer a number of fluorescent indicators for measuring Na+ and K+. Review Fluorescent Na+ and K+ Indicators—Section 21.1 in the Molecular Probes™ Handbook for more information on these products.

For Research Use. Not for human or animal therapeutic or diagnostic use.

Order Info

Shipping Condition: Room temperature

Specifications

Content And Storage Store at room temperature and protect from light.
Detection Method Fluorescence
For Use With (Application) Potassium Ion Channel
For Use With (Equipment) Fluorescence Microscope
Product Type PBFI
Dye Type PBFI
Excitation Wavelength Range 330 to 345 nm, 375 to 390 nm
Quantity 1 mg
Shipping Condition Room Temperature
Emission Wavelength Range 495 to 510 nm
Excitation Wavelength 340 nm, 380 nm
Emission Wavelength 500 nm
Show More Show Less

For Research Use Only. Not for use in diagnostic procedures.