Ion Chromatography Instruments
Résultats de la recherche filtrée
Biochrom Bio32+ Sodium Oxidized Protein Hydrolysate Systems
Designed for the analysis of complex oxidised hydrolysates such as those obtained from food and feedstuffs. Animal feedstuff, pet food, and the human food industry.
| Gamme de température (métrique) | Column temperature variable between 20°C to 99°C. Reaction coil temperature adjustable between 40°C to 145°C (135°C is optimum) |
|---|---|
| Poids (impériale) | Bench top Fluidics Cabinet: 110 lb.; Autosampler: 46 lb. |
| Pression max. | Buffer pressure: maximum 150 bar; Ninhydrin pressure: maximum 24 bar |
| Type de colonne | High pressure PEEK column packed with Ultropac 8 cation exchange resin. Peltier heating/cooling system |
| Type de détecteur | Ninhydrin - post column derivatization |
| Poids (métrique) | Bench top Fluidics Cabinet: 50 kg; Autosampler: 21 kg |
Thermo Scientific™ POROS™ HQ 50 μm Strong Anion Exchange Resin
POROS XQ is a high-capacity, high-resolution, salt-tolerant resin that enables >140 mg/mL dynamic binding capacity while delivering exceptional separation performance
| Type | HQ Strong Anion Exchange Resin |
|---|---|
| Format | Poros Bead |
| Gamme de produits | POROS |
| Composants standard | Quaternized Polyethyleneimine |
| Cible de purification | Protein |
| Conditions d’expédition | Room Temperature |
| Phase stationnaire | Quaternized Polyethyleneimine |
| Contenu et stockage | Store in refrigerator (2–8°C). |
| À utiliser avec (application) | Separation and Purification of Biomolecules |
Biochrom Bio30+ Lithium Physiological Systems
Dedicated chromatographic bench top system for Amino Acid Analysis
| Gamme de température (métrique) | Column temperature variable between 20°C to 99°C. Reaction coil temperature adjustable between 40°C to 145°C (135°C is optimum) |
|---|---|
| Type | IC System |
| Poids (impériale) | Bench top Fluidics Cabinet: 110 lb.; Autosampler: 46 lb. |
| Pression max. | Buffer pressure: maximum 150 bar; Ninhydrin pressure: maximum 24 bar |
| Type de colonne | High pressure PEEK column packed with Ultropac 8 cation exchange resin. Peltier heating/cooling system |
| Type de détecteur | Ninhydrin - post column derivatization |
| Poids (métrique) | Bench top Fluidics Cabinet: 50 kg; Autosampler: 21 kg |
Biochrom Bio31+ Sodium Protein Hydrolysate Systems
Dedicated chromatographic bench top system for Amino Acid Analysis
| Gamme de température (métrique) | Column temperature variable between 20°C to 99°C. Reaction coil temperature adjustable between 40°C to 145°C (135°C is optimum) |
|---|---|
| Type | IC System |
| Poids (impériale) | Bench top Fluidics Cabinet: 110 lb.; Autosampler: 46 lb. |
| Pression max. | Buffer pressure: maximum 150 bar; Ninhydrin pressure: maximum 24 bar |
| Type de colonne | High pressure PEEK column packed with Ultropac 8 cation exchange resin. Peltier heating/cooling system |
| Type de détecteur | Ninhydrin - post column derivatization |
| Poids (métrique) | Bench top Fluidics Cabinet: 50 kg; Autosampler: 21 kg |
Thermo Scientific™ POROS™ XS Strong Cation Exchange Resin
POROS XS is the first high-capacity, high-resolution resin that allows loading to >100 mg/mL in the presence of 15 mS/cm NaCl, while delivering unprecedented separation capability
| Type | XS Strong Cation Exchange Resin |
|---|---|
| Format | Poros Bead |
| Gamme de produits | POROS |
| Composants standard | Crosslinked Poly(styrene-divinylbenzene) |
| Cible de purification | Protein |
| Conditions d’expédition | Room Temperature |
| Phase stationnaire | XS |
| Contenu et stockage | Store in refrigerator (2–8°C). |
| À utiliser avec (application) | Cation Exchange Chromatography |
Thermo Scientific™ POROS™ XQ Strong Anion Exchange Resin
POROS XQ is a high-capacity, high-resolution, salt-tolerant resin that enables >140 mg/mL dynamic binding capacity while delivering exceptional separation performance
| Type | XQ Strong Anion Exchange Resin |
|---|---|
| Format | Poros Bead |
| Gamme de produits | POROS |
| Composants standard | Quaternized Polyethyleneimine |
| Cible de purification | Protein |
| Conditions d’expédition | Room Temperature |
| Phase stationnaire | Quaternized Polyethyleneimine |
| Contenu et stockage | Store in refrigerator (2–8°C). |
| À utiliser avec (application) | Strong Anion Exchange Chromatography |