Syringeless and Syringe Filters
- (8)
- (15)
- (286)
- (9)
- (92)
- (1)
- (397)
- (1)
- (14)
- (16)
- (2)
- (3)
- (20)
- (1)
- (16)
- (1)
- (2)
- (5)
- (2)
- (1)
- (3)
- (3)
- (27)
- (3)
- (9)
- (1)
- (2)
- (9)
- (72)
- (4)
- (17)
- (1)
- (4)
- (37)
- (1)
- (19)
- (2)
- (133)
- (99)
- (2)
- (98)
- (1)
- (37)
- (50)
- (109)
- (23)
- (2)
- (1)
- (8)
- (3)
- (8)
- (63)
- (26)
- (572)
- (153)
- (11)
- (471)
- (21)
- (32)
- (13)
- (22)
- (187)
Filtered Search Results
Basix™ Syringe Filters, PES, Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PES, Sterile offers high sample throughput.
| Diameter (Metric) | 25 mm |
|---|---|
| Housing Material | Acrylic |
| Material (Membrane) | PES |
| Sterility | Sterile |
Fisherbrand™ Syringe Filters - Sterile
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Hold up Volume (After Air Purge) | Low |
MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.
| Pore Size | 0.22 μm |
|---|---|
| Disposable | Single-use |
| Temperature (English) Operating | 113°F |
| Housing Material | Hydrophilic PES |
| Material (Membrane) | PES |
| Color | Green |
| Volume (Metric) | <10 mL |
| Pressure Rating | 145 psi |
| For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
| Sterility | Sterile |
| Type | Modified Acrylic Syringe Filter |
| Outlet Style | Male Luer Slip |
| Diameter (Metric) | 3.3 cm |
| Inlet Style | Female Luer Lock |
| Tip Material | Modified Acrylic |
| Temperature Range (English) | 113°F |
| Temperature Range (Metric) | 45°C |
| Temperature (Metric) Operating | 45°C |
| Autoclavable | Not Autoclavable |
| Hold up Volume (After Air Purge) | <100 μL |
Basix™ Syringe Filters, Nylon, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | Nylon |
| Sterility | Non-sterile |
MilliporeSigma™ Millex™-GV Sterile Syringe Filter Unit, PVDF, 0.22 μm
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
| Pore Size | 0.22 μm |
|---|---|
| Disposable | Single-use |
| Temperature (English) Operating | 113°F |
| Housing Material | PVDF |
| Material (Membrane) | PVDF (Hydrophilic) |
| Color | Yellow |
| For Use With (Application) | Ultra-low protein binding; Sterilization of tissue culture media, protein solutions or aqueous solutions |
| Sterility | Sterile |
| Type | Syringe Filter |
| Inlet Style | Female Luer Lock |
| Temperature Range (English) | 113°F |
| Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
| Temperature Range (Metric) | 45°C |
| Temperature (Metric) Operating | 45°C |
| Autoclavable | Not Autoclavable |
Thermo Scientific™ Nalgene™ Syringe Filters
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Filter sample volumes of 10 to 100mL with these sterile syringe filters featuring a variety of membranes and pore sizes for most laboratory applications.
| Type | Syringe Filter |
|---|---|
| Housing Material | Polypropylene |
Basix™ Syringe Filters, PTFE, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PTFE, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | PTFE (Hydrophobic) |
| Sterility | Non-sterile |
| Outlet Style | Male Leur-Slip |
|---|---|
| Diameter (Metric) | 33 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Acrylic |
| Material (Membrane) | PES |
| Quantity | 50/Pk. |
| Sterility | Sterile |
Fisherbrand™ Syringe Filters: PTFE Membrane
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Material | PTFE |
| For Use With (Application) | Ideal for degassing/clarifying aqueous and solvent samples |
Basix™ Syringe Filters, Nylon, Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Sterile offers high sample throughput.
| Diameter (Metric) | 25 mm |
|---|---|
| Housing Material | Acrylic |
| Material (Membrane) | Nylon |
| Sterility | Sterile |
Choice™ PES (Polyethersulfone) Syringe Filters
Use Choice PES (Polyethersulfone) Syringe Filters for ion chromatography samples, and filtration of tissue cultures, proteins, nucleic acids, and high-temperature liquids.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | PES |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
Choice™ Regenerated Cellulose Syringe Filters
Use Choice Regenerated Cellulose Syringe Filters for low nonspecific binding applications, tissue culture media filtration, and general biological sample filtration.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | Regenerated Cellulose |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
| Pore Size | 0.22 μm |
|---|---|
| Disposable | Single-use |
| Temperature (English) Operating | 113°F |
| Housing Material | Modified Acrylic |
| Material (Membrane) | PES |
| Color | Green |
| Pressure Rating | 145 psi |
| For Use With (Application) | Low protein binding; sterilization of tissue culture media, protein solutions or aqueous solutions; Sterilization of drugs or aqueous solutions administered intravenously |
| Sterility | Sterile |
| Type | Modified Acrylic Syringe Filter |
| Outlet Style | Male Luer Slip |
| Diameter (Metric) | 3.3 cm |
| Inlet Style | Female Luer Lock |
| Tip Material | Modified Acrylic |
| Temperature Range (English) | 113°F |
| Filter Type | Membrane Filter |
| Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
| Temperature Range (Metric) | 45°C |
| Temperature (Metric) Operating | 45°C |
| Autoclavable | Not Autoclavable |
| Hold up Volume (After Air Purge) | <100 μL |
Sartorius Minisart™ PES Syringe Filters
Minisart™ PES with polyethersulfone (PES) is optimal for highest flow rates and a pH of 2 - 13. Type 1776D with a pore size of 0.22 μm can be used for sterile filtration and has a male luer slip outlet. Version ACK is individually packed and sterilized by ethylene oxide (EO).