SPE Plates
- (16)
- (10)
- (1)
- (1)
- (1)
- (10)
- (11)
- (2)
- (1)
- (15)
- (1)
- (1)
- (5)
- (47)
- (4)
- (60)
- (26)
- (10)
- (5)
- (21)
- (2)
- (13)
- (2)
- (2)
- (5)
- (12)
- (1)
- (6)
- (20)
- (1)
- (1)
- (3)
- (4)
- (1)
- (6)
- (8)
- (7)
- (5)
- (6)
- (3)
- (1)
- (1)
- (2)
- (1)
- (3)
- (4)
- (7)
- (1)
- (3)
- (3)
- (3)
- (2)
- (3)
- (53)
- (4)
- (14)
Filtered Search Results
Thermo Scientific™ HyperSep™ Silica Plates
Retain analytes in nonpolar matrices, and separate compounds of very similar structure with these silica SPE well plates and individual wells.
| Particle Size | 40 to 60 μm |
|---|---|
| Type | Solid Phase Extraction Well Plate |
| Quantity | 1 Pk. |
| Volume (Metric) Well | 1 mL |
| Sorbent | HyperSep Silica |
| For Use With (Application) | Retention of Analytes in Nonpolar Matrices |
| Product Line | HyperSep |
Thermo Scientific™ HyperSep™ Solid Phase Extraction (SPE) Accessories, Empty Wells
These empty 1mL wells are used with Thermo Scientific™ HyperSep 96-well plate applications.
| For Use With (Equipment) | HyperSep-96 Products and Compatible Manifolds |
|---|
Thermo Scientific™ HyperSep™ Aminopropyl Plates
Obtain excellent retention of drugs, metabolites and structural isomers with these aminopropyl SPE well plates that allow both polar and anion exchange interactions.
| Particle Size | 40 to 60 μm |
|---|---|
| Type | Solid Phase Extraction Well Plate |
| Quantity | 1 Pk. |
| Sorbent | HyperSep Aminopropyl |
| For Use With (Application) | Extraction of Strong Acids via Polar and Anion Exchange Interactions |
| Product Line | HyperSep |
Thermo Scientific™ HyperSep™ Cyano Plates
Get optimized isolation of polar compounds from nonpolar matrices, with these medium polarity cyano SPE well plates and individual wells.
| Particle Size | 40 to 60 μm |
|---|---|
| Type | Solid Phase Extraction Well Plate |
| Quantity | 1 Pk. |
| Sorbent | HyperSep Cyano |
| For Use With (Application) | Retention of Polar Compounds From Nonpolar Matrices |
| Product Line | HyperSep |
MilliporeSigma™ HybridSPE™-Phospholipid Small Volume 96-well Plate
HybridSPE™ Phospholipid Removal Technology for Biological Matrices. Remove phospholipids and proteins for accurate and reproducible LC-MS analysis.
| Type | Fritless SPE Cartridge and Plates |
|---|---|
| Bed Weight | 15 mg |
| Volume (Metric) | 0.8 mL |
| For Use With (Application) | Food and Beverage |
Thermo Scientific™ SMART Digest™ Immunoaffinity (IA) Protein G Kits
Quantitate low-level biotherapeutics and biomarkers faster, easier, and quicker by performing highly reproducible immunocapture and protein digestion in a single well.
| Type | Immunocapture + Protein Digestion combined on a single bead |
|---|---|
| Enzyme | Trypsin |
| Cleavage | C-terminal side of lysine and arginine amino acids |
| For Use With (Application) | Peptide Quantitation |
| Capture | Protein G |
| Product Line | SMART Digest |
Thermo Scientific™ SMART Digest™ Proteinase K Kits
Obtain fast, simple, highly reproducible, and sensitive immunocapture and protein digestion in a single well for your biomarker studies.
| Type | Protein Digestion |
|---|---|
| Enzyme | Proteinase K |
| Cleavage | Peptide bond adjacent to carboxyl group of aliphatic and aromatic amino acids with blocked alpha amino groups |
| For Use With (Application) | Peptide Quantitation, Peptide Mapping |
| Capture | None |
| Product Line | SMART Digest |
MilliporeSigma™ Supelco™ SPE 96-Deep Square Well Collection Plate
Solid phase extraction (SPE) is a technique commonly used in laboratories to isolate analytes of interest from complex matrices.
| Type | 96-well Plate |
|---|---|
| Column Type | SPE |
| Quantity | 50/Pk. |
| Material | Polypropylene |
| For Use With (Application) | Food and Beverages |
Thermo Scientific™ SMART Digest™ ImmunoAffinity (IA) Streptavidin Kits
Obtain fast, simple, highly reproducible, and sensitive streptavidin immunocapture and trypsin protein digestion in a single well for your biomarker studies.
| Type | Immunocapture + Protein Digestion combined on a single bead |
|---|---|
| Enzyme | Trypsin |
| Cleavage | C-terminal side of lysine and arginine amino acids |
| For Use With (Application) | Peptide Quantitation |
| Capture | Streptavidin |
| Product Line | SMART Digest |
Thermo Scientific™ HyperSep™ Retain PEP Plates
Get balanced retention for polar and nonpolar analytes with HyperSep Retain PEP Plates.
| Particle Size | 30 to 50 μm |
|---|---|
| Type | Solid Phase Extraction Well Plate |
| Quantity | 1 Pack |
| Volume (Metric) Well | 1 mL |
| Sorbent | HyperSep Urea-Modified Polystyrene DVB |
| For Use With (Application) | Retention of Polar and Nonpolar Analytes |
| Product Line | HyperSep |
Thermo Scientific™ HyperSep™ SCX Strong Cation Exchanger SPE 96-Well Plates and Individual Wells
Obtain excellent performance for extraction of charged basic compounds with these strong cation exchanger SPE well plates and individual wells.
Thermo Scientific™ HyperSep™ Retain AX SPE 96-Well Plates and Individual Wells
Achieve superior recoveries for acidic analytes with Thermo Scientific™ HyperSep™ Retain AX SPE Cartridges.
Thermo Scientific™ Hypersep™ Hypercarb™ Fixed Well Plate
Unique material for retention of highly polar compounds.
| Particle Size | 40 to 60 μm |
|---|---|
| Type | 96-well Plate |
| For Use With (Equipment) | Universal Vacuum Manifold |
| Quantity | 1/Ea |
| Sorbent | HypeSep Hypercarb |
| Product Line | HyperSep |