Hamilton™ PRP-X100 Anion Exchange HPLC Columns: PEEK
GREENER_CHOICE

Polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm

$1259.36 - $1681.77

Specifications

For Use With Analysis of Fluoride, Carbonate, Chloride, Nitrite, Bromide, Nitrate, Phosphate, Sulfate and Other Ions
Max. Pressure 5000 psi (345 bar)
Mobile Phase Compatibility pH 1 to 13, 0 to 100% aqueous, organic modifier
pH 1 to 13
Pore Size 100 Ă…
View More Specs

Products 4
Catalog Number Mfr. No. Particle Size Flow Rate Column Format Price Quantity  
Catalog Number Mfr. No. Particle Size Flow Rate Column Format Price Quantity  
14-816-71
View Documents
Hamilton™
HAM79354
10 ÎĽm 8 mL/min 150 x 4.6 mm
Each for $1,259.36
Only null left
 
13-622-555
View Documents
Hamilton™
HAM79174
5 ÎĽm 1 mL/min 150 x 4.6 mm L x ID
Each for $1,442.92
Only null left
 
14-816-109
View Documents
Hamilton™
HAM79455
10 ÎĽm 1 mL/min Analytical Column
Each for $1,585.09
Only null left
 
13-622-556
View Documents
Hamilton™
HAM79181
5 ÎĽm 1 mL/min 250 x 4.6 mm L x ID
Each for $1,681.77
Only null left
 
Description

Description

Easy Ion Determination

  • PRP-X100 ion chromatography columns are the easy way to separate inorganic ions.These columns can be used with any existing HPLC or ion chromatograph to easily determine anions in almost any sample matrix including air, water and soil.
Better than Wet Chemical Methods
  • Ion chromatography greatly reduces sample pretreatment and improves the accuracy and precision of results when using wet chemical or colorimetric methods
High Sensitivity
  • Use to separate ions at concentrations from 1 ppm to 1,000 ppm without suppression or elaborate preconcentration techniques
Long Column Life
  • Highly inert polymeric support resists chemical attack from organic solvents and aqueous buffers (0-100% aqueous or organic; pH 1 to 13), effectively lengthening column life. If column performance should deteriorate (peak broadening and a loss of symmetry), the regeneration protocol will usually return chromatography to its original state.
Analyze Both Difficult and Common Anions
  • Easily separate difficult anions such as cyanide, borate and silicate at high pH (11.5). The polymeric packing is stable from pH 1 to 13, so a single column can be used for the analysis of both common and difficult anions.
Easy Detection and Common Eluents
  • Conductivity detection works by measuring the increased conductance of the eluting sample ions relative to the background conductance

Specifications

Specifications

Analysis of Fluoride, Carbonate, Chloride, Nitrite, Bromide, Nitrate, Phosphate, Sulfate and Other Ions
pH 1 to 13, 0 to 100% aqueous, organic modifier
100 Ă…
PRP-X100
Ion Exchange
PEEK
5000 psi (345 bar)
1 to 13
5°C to 60°C
PSDVB/Trimethylammonium
Ion Exchange
Column