Applied Biosystems™ Calibration Install Kit, 384-well
Description
Includes
- 1 ROI calibration plate
- 6 spectral calibration plates with FAM™, SYBR™ Green, VIC™, NED™, TAMRA™, and ROX™ dye standards
- 2 normalization plates with FAM™/ROX™ and VIC™/ROX™
- 1 RNase P instrument verification plate
It includes calibration plates to perform a spectral calibration with FAM™, VIC™, ROX™, SYBR™ Green, TAMRA™, and NED™ dyes, as well as plates to perform region-of-interest (ROI) calibration, normalization calibration, and RNase P verification. Calibration and verification should be done at least every six months. Please see your instrument maintenance guide for full instructions on use. The dye formulations for your real-time PCR system will improve results with multiplexing by more accurately representing fluorescent spectra found in your real-time PCR experiments.
Calibration and verification should be done at least every six months. Please see instrument maintenance guide for full instructions.
Order Info
Store kit at -5° to -30°C
Specifications
Specifications
| Content And Storage | • 1 background plate • 1 ROI calibration plate • 6 spectral calibration plates with FAM™ SYBR™ Green, VIC™, NED™, TAMRA™, and ROX™ dye standards • 2 normalization plates with FAM™/ROX™ and VIC™/ROX™ • 1 RNase P instrument verification plate Store kit at -5°C to -30°C. |
| For Use With (Equipment) | QuantStudio™ 12 K Flex, QuantStudio™ 6 Flex, QuantStudio™ 7, ViiA™ 7 System |
| Product Type | Calibration Install Kit |
| For Use With (Application) | Real Time PCR (qPCR) |
| Quantity | 1 kit |
| Calibration Type | Spectral Calibration |
Frequently Asked Questions (FAQs)
To open the software download on your Mac, you will need to adjust your security settings using the following instructions from Apple support:
Safely open apps on your mac
Please note, the software should run on Mac OS 10.10 or later.
You can get a summary of the calibrations from the QuantStudio Software by going to Instrument > Instrument Console > Manage Instrument > Information > Print Calibration Log.
No, you do not need to back up the calibration files as all of the calibration files are stored on the ViiA7 Real-Time PCR instrument. Once the computer software is properly installed and the computer is connected to the instrument, the calibration information will automatically update in the QuantStudio Software.
Yes, you can still start a run on the ViiA7 Real-Time PCR System if the expired calibration notice displays. This is just a reminder and you can close it to proceed with the run. Additionally, you can change when you want the notifications to show up and how frequently you want to be notified to calibrate the instrument. To do this, go to the toolbar in the QuantStudio Software and select Instrument > Instrument Console. Select your instrument icon and click on Manager Instrument > Maintenance > Calibration Reminders. From the Calibration reminders Settings page you can update when the calibrations expire, turn expiration reminders on/off, and set when the reminders show up.