missing translation for 'onlineSavingsMsg'
Learn More

Labconco™ Protector™ XL Floor-Mounted Fume Hoods: 12 ft. Width

Suitable for general chemistry applications and accommodates oversized apparatus

$62098.13 - $67911.91

Specifications

Product Type Horizontal Sash Fume Hood
Coating Powder
Lighting Type LED
Material Polyester
Amperage 10 A
View More Specs

Products 3
Catalog Number Mfr. No. Depth (Metric) Weight (Metric) Price Quantity  
Catalog Number Mfr. No. Depth (Metric) Weight (Metric) Price Quantity  
11-211-6002
View Documents
Labconco™
112116002
95.8 cm 548.8 kg N/A
N/A
Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
11-212-6002
View Documents
Labconco™
112126002
111 cm 555.7 kg N/A
N/A
Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
11-213-6002
View Documents
Labconco™
112136002
141.5 cm 569.3 kg N/A
N/A
Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
Description

Description

  • By-pass airflow design
  • Dry powder, glacier white epoxy-coated steel exterior
  • Chemical-resistant molded composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84
  • Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring
  • Pre-wired light and blower switches for 115V, 60Hz operation
  • Tempered safety glass horizontal-sliding sashes with epoxy-coated aluminum frames and sash tracks
  • Factory prepared for up to eight service fixtures including two gooseneck faucets
  • Factory prepared for up to four electrical duplex receptacles
  • Shipped in multiple sections, top and bottom
  • Epoxy-coated, stainless-steel 12.81 in. ID exhaust connection(s)
  • ETL listed
  • LED lighting
Compliance
  • SEFA 1-2014 (Laboratory Fume Hoods)
  • NFPA 45-2011 (Fire Protection for Laboratories Using Chemicals) section 6-1 through 6-14
  • ASTM E84-14 Surface Burning Characteristics of Building Materials
  • ASHRAE 110-95 (Method of Testing Performance of Laboratory Fume Hoods)
  • ANSI Z9.5-2012 (Laboratory Ventilation)
  • UL 3101-1/61010-1
  • CAN/CSA C22.2 No. 1010.1
  • UL 1805
Specifications

Specifications

Horizontal Sash Fume Hood
LED
10 A
241.3 cm
2 Service fixtures, 2 GFCI duplexes
115 V
365.8 cm
Powder
Polyester
95 in.
60 Hz
Domestic
144 in.
Videos
SDS
missing translation for 'documents'

missing translation for 'documents'