missing translation for 'onlineSavingsMsg'
Learn More
Please login to your online account to display your discounted pricing

Thermo Scientific™ Matrix™ Filtered Pipette Tips

Eliminate pipetter barrel contamination with Thermo Scientific™ Matrix™ Filtered Pipette Tips.

$441.09 - $2,192.14

Specifications

Sterility Sterile
View More Specs


Products ${productFamilyLength}
Catalog Number Mfr. No. For Use With (Equipment) Packaging Volume (Metric) Price Quantity  
Catalog Number Mfr. No. For Use With (Equipment) Packaging Volume (Metric) Price Quantity  
14-387-171 Thermo Scientific™
MX7155
Matrix Impact 30μL single channel 10 x 96/Rack 30μL Case of 960 Each for $466.69
14-387-173 Thermo Scientific™
MX7275
Gilson/Rainin P200 10 x 96/Rack 200μL Case of 960 Each for $441.09
14-387-177 Thermo Scientific™
MX7325
Gilson/Rainin P200 10 x 96/Rack 250μL Case of 960 Each for $441.09
14-387-193 Thermo Fisher Scientific
MX742511
Thermo Scientific Matrix Pipettes Rack, 10 x 384 12.5μL Case of 3840 Each for $2,192.14
14-387-196 Thermo Scientific™
MX7435
Equalizer 384 Rack, 10 x 384 30μL Case of 3840 Each for $2,192.14
14-387-199 Thermo Scientific™
MX7445
Equalizer 384 Rack, 10 x 384 125μL Case of 3840 Each for $2,192.14
14-387-186 Thermo Scientific™
MX7615
Gilson Rainin Pipetteman P2, P10, P20 10 x 96/Rack 10μL Case of 960 Each for $441.09
14-387-181 Thermo Scientific™
MX8045
Matrix Impact 850-1250μL 10 x 96/Rack 1250μL Case of 960 Each for $566.46
14-387-096 Thermo Scientific™
MX8055
Thermo Scientific Matrix Pipettes Racks, 6 x 120 1250μL Case for $573.00
14-387-190 Thermo Fisher Scientific
MX7625
10 x 96/Rack 10μL Case of 960 Each for $449.14
Specifications

Description

Eliminate pipetter barrel contamination with Thermo Scientific™ Matrix™ Filtered Pipette Tips. Rigorously tested to ensure optimum performance, these filtered tips eliminate the risk of cross-contamination from aerosols created while pipetting genomic material, bacterial samples or other precious samples.

Benefits:
  • Stringent testing guarantees filter tips that effectively block aerosols.
  • Hydrophobic polyethylene filter material ensures no particulates contaminate samples.
  • Inadvertent contact with filter will not contaminate sample or result in sample loss.
  • Easy to open packaging maintains product sterility while providing easy access.
  • Hinged lid allows rack to be opened without laying lid on benchtop, helping maintain sterility.
  • Racks are sealed in thick polyethylene bag for sterility, which is easy to open with simple snap-and-tear packaging.

Stringent Filter Testing:

  • Filter must meet certain porosity requirements and must form a complete barrier across face of tip.
  • To ensure defects are not present, two specific tests are performed: mercury intrusion and particle count testing.
  • Mercury Intrusion Testing (QC 13.1 - QC 13.8) ensures the filter itself meets specific aerosol blocking requirements.
  • Particle Count Testing (Test Protocol QAS-0100) ensures filter is effective at blocking aerosols after installation into tip; also ensures proper shape and fit of filter.
  • Every lot of tips is tested by drawing a vacuum of aerosols against the filter and ensuring particles do not pass through.

Recommended for:

  • Bacteriology
  • Gel loading
  • PCR setup
  • Preventing cross-contamination during routine pipetting
Description & Specifications

Specifications

Sterile