Please login to your online account to display your discounted pricing

Labconco™ Protector™ XL Floor-Mounted Fume Hoods: 16 ft. Width

Suitable for general chemistry applications and accommodates oversized apparatus

Specifications

Electrical Requirements 115V, 60Hz, 10A, Domestic
Lighting T8 fluorescent
Width (Metric) 487.7cm
Height Overall (Metric) 241.3cm
Includes 2 Service fixtures, 2 GFCI duplexes
View More Specs
Products
Catalog Number Mfr. No. Depth (Metric) Weight (Metric) Price Quantity    

11-222-6002

 
labconco™
LCN112226002
111cm 750.7kg CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

11-221-6002

 
labconco™
LCN112216002
95.8cm 743.9kg CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

11-223-6002

 
labconco™
LCN112236002
141.5cm 764.3kg CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
Description & Specifications

Specifications

Electrical Requirements 115V, 60Hz, 10A, Domestic
Lighting T8 fluorescent
Width (Metric) 487.7cm
Height Overall (Metric) 241.3cm
Includes 2 Service fixtures, 2 GFCI duplexes

  • By-pass airflow design
  • Dry powder, glacier white epoxy-coated steel exterior
  • Chemical-resistant molded composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84
  • ;Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring
  • Pre-wired instant-start T8 fluorescent lighting, light and blower switches for 115V, 60Hz operation
  • Tempered safety glass horizontal-sliding sashes with epoxy-coated aluminum frames and sash tracks
  • Factory prepared for up to eight service fixtures including two gooseneck faucets
  • Factory prepared for up to four electrical duplex receptacles
  • Shipped in multiple sections, top and bottom
  • Shipped in multiple sections, top and bottom
  • ETL listed
Compliance
  • SEFA 1-2014 (Laboratory Fume Hoods)
  • NFPA 45-2011 (Fire Protection for Laboratories Using Chemicals) section 6-1 through 6-14
  • ASTM E84-14 Surface Burning Characteristics of Building Materials
  • ASHRAE 110-95 (Method of Testing Performance of Laboratory Fume Hoods)
  • ANSI Z9.5-2012 (Laboratory Ventilation)
  • UL 3101-1/61010-1
  • CAN/CSA C22.2 No. 1010.1
  • UL 1805