Please login to your online account to display your discounted pricing

Labconco™ Protector™ Stainless-Steel Perchloric Acid Hood

The Type 316 stainless-steel interior of the Labconco Protector™ Stainless-Steel Perchloric Acid Hood withstands reaction and helps keep your lab safe.

Specifications

Lighting Fluorescent
View More Specs
Requires:  Remote blowers, ductwork, base cabinets, adjustable height base stands
Products
Catalog Number Mfr. No. Electrical Requirements Includes Pressure Price Quantity    

13-118-201

 
labconco™
130400001
115V 50/60Hz Service fixtures: 2 725cfm at 0.25 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-202

 
labconco™
130400002
115V 50/60Hz Service fixtures: 2; Receptacle: 1 725cfm at 0.25 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-200

 
labconco™
130400000
115V 50/60Hz No service fixtures 725cfm at 0.25 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-210

 
labconco™
130500000
115V 50/60Hz No service fixtures 955cfm at 0.33 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-211

 
labconco™
130500001
115V 50/60Hz Service fixtures: 2 955cfm at 0.33 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-212

 
labconco™
130500002
115V, 50/60Hz Service fixtures: 2; Receptacle: 1 955cfm at 0.33 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-221

 
labconco™
130600001
115V, 50/60Hz Service fixtures: 2 1180cfm at 0.50 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-220

 
labconco™
130600000
115V, 50/60Hz No service fixtures 1180cfm at 0.50 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-222

 
labconco™
130600002
115V, 50/60Hz Service fixtures: 2; Receptacle: 1 1180cfm at 0.50 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-230

 
labconco™
130800000
115V, 50/60Hz No service fixtures 1640cfm at 0.28 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-231

 
labconco™
130800001
115V 50/60Hz Service fixtures: 2 1640cfm at 0.28 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

13-118-232

 
labconco™
130800002
115V, 50/60Hz Service fixtures: 2; Receptacle: 1 1640cfm at 0.28 in. H2O at 100fpm CALL N/A N/A
 Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.
Description & Specifications

Specifications

Lighting Fluorescent

 

  • By-pass airflow design
  • Glacier white, dry powder powder-coated steel exterior
  • Curved ergonomic air foil with aerodynamic Clean-Sweep™ airflow openings
  • Type 316 stainless-steel liner (23.5 in. interior depth) with radiused corners, integral work surface, drainage trough and pre-set baffles
  • Black enamel-coated hardboard surface to support the integral work surface
  • 0.18 in. Thick tempered safety glass vertical rising sash with frame of powder-coated aluminum and PVC
  • Sash does not extend above the hood when fully open
  • Removable front and side panels and front access panels for access to plumbing and electrical wiring
  • Built-in washdown system with internal piping and spray nozzles behind the baffle and remote control fixture on upper left side
  • Washdown fitting located on top of hood to facilitate connection to external wash rings (wash rings not included)
  • Two pre-plumbed service fixtures with forged brass valves and chrome-plated brass serrated hose connectors, lower right side with brass tubing for gas and lower left side with copper tubing for air
  • Components for converting either or both fixtures to cold water and vacuum are provided
  • Energy-efficient T8 fluorescent lighting
  • Pre-wired 115/230V electrical duplex receptacle on lower right side
  • 11 in. O.D. Type 316 stainless-steel exhaust connection(s)

 

Air usage/static pressure with sash full open (at 100fpm)

  • 4 ft. Model: 725cfm at 0.17 in.
  • 5 ft. Model: 955cfm at 0.33 in.
  • 6 ft. Model: 1180cfm at 0.50 in.

 

Available in 4, 5 and 6 ft. width

ETL Listed, UL 3101-1/61010-1, UL 1805

SEFA 1-2002, NFPA 45-2004, ASTM™ E84-01, ASHRAE™ 110-95, ANSI™ Z9.5-2003, CAN/CSA C22.2 No. 1010.1