missing translation for 'onlineSavingsMsg'
Learn More
Please login to your online account to display your discounted pricing

Isooctane, Optima™ for HPLC and GC, Fisher Chemical™

High purity and versatile solvent suitable for HPLC and pesticide residue analysis

Supplier:  Thermo Fisher Scientific O2961

 View more versions of this product

Catalog No. O296-1




Description

Description

  • Screened for fluorescing and UV-absorbing contaminants to reduce interferences for smoother baselines
  • Tested by GC-ECD to ensure minimum halogenated residue levels (≤10 ng/L) to demonstrate suitability for pesticide analysis
  • Also meets ACS specifications
  • Intended for research use only
Specifications

Specifications

Isooctane
540-84-1
Colorless
98°C
-12°C (10.4°F)
Petroleum distillates
Liquid
1.3885 to 1.3905 (at 25°C)
≥99 %
MFCD00008943
0.51 mPa/s at 22°C
0.02% max.
Solubility in water: insoluble
CC(C)CC(C)(C)C
114.232
CHEBI:62805
≥99%
-107°C
0.014 AU max. at 254nm, 0.1 AU max. at 225nm, 1.0 AU max. at 205nm
0.690g/cm³
1 L
Pass Test
Wide Neck Amber Bottle
Also meets ACS specifications
4ppm max.
C8H18
51mbar at 20°C
1262
isooctane, isobutyltrimethylmethane, pentane, 2,2,4-trimethyl, iso-octane, 2,4,4-trimethylpentane, unii-qab8f5669o, ch3 2chch2c ch3 3, 2, 2, 4-trimethylpentane, i-octane, isobutyltrimethylethane
NHTMVDHEPJAVLT-UHFFFAOYSA-N
2,2,4-trimethylpentane
10907
114.23
HPLC

Chemical Identifiers

540-84-1
114.232
isooctane, isobutyltrimethylmethane, pentane, 2,2,4-trimethyl, iso-octane, 2,4,4-trimethylpentane, unii-qab8f5669o, ch3 2chch2c ch3 3, 2, 2, 4-trimethylpentane, i-octane, isobutyltrimethylethane
CHEBI:62805
CC(C)CC(C)(C)C
C8H18
NHTMVDHEPJAVLT-UHFFFAOYSA-N
10907
2,2,4-trimethylpentane
Safety and Handling

Safety and Handling

DANGER!

Emergency Overview
Flammable liquid and vapor. Vapors may cause drowsiness and dizziness. Aspiration hazard if swallowed - can enter lungs and cause damage. Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment. Use personal protective equipment. Keep away from open flames, hot surfaces and sources of ignition. Use only under a chemical fume hood. Wash off immediately with plenty of water for at least 15 minutes. Obtain medical attention. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Obtain medical attention. Move to fresh air. Move to fresh air. If breathing is difficult, give oxygen.

NFPA

Health:1
Flammability:3
Instability:0

DOTInformation : DOT Class 3, : Flammable Liquid

Recommended Storage : Keep away from open flames, hot surfaces and sources of ignition. Keep containers tightly closed in a dry, cool and well-ventilated place. Flammables area. Keep away from heat and sources of ignition.

SDS Documents

Documents

Accessories
Promotions

Promotions