Please login to your online account to display your discounted pricing

Thermo Scientific™ Acclaim™ Explosives E2 LC Columns


Achieve baseline resolution of all 14 explosives listed in EPA Method 8330 with Thermo Scientific™ Acclaim™ Explosives E2 LC Columns.

Manufacturer: thermo scientific™  064309

 View more versions of this product

 Disclaimers

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Catalog No. DX064309

  • / Each
 

Description & Specifications

Specifications

Metal Impurity <10.0ppm Total Metal, <3.0ppm Individual Metal
Column Format Analytical Column
Diameter (Metric) 4.6mm
Flow Rate 0.8 to 1.5mL/min.
Endcapped Yes
Pore Size 120Å
USP Type N/A
Carbon Load -
Packing Material Spherical, fully porous ultrapure silica
Max. Pressure 400bar
For Use With LC/MS
Column Type Speciality / Application Specific
Length (Metric) 250mm
Particle Size 3µm
pH 2.5 to 7.5
Surface Area 300m²/g
Type Analytical Column
Temperature 50°C
Particle Shape Spherical
Stationary Phase Proprietary

Achieve baseline resolution of all 14 explosives listed in EPA SW-846 Method 8330 with Thermo Scientific™ Acclaim™ Explosives E2 LC Columns, Nitroaromatics and Nitramines by HPLC. Their unique column chemistries deliver superior resolution with complementary selectivities. Use the E1 column (available separately) as a direct replacement for ODS columns for primary analysis. Then, use the E2 column as either a primary or a confirmatory column. Easily change the separation conditions for the E2 column to accommodate a wider application range, including the analysis of explosives beyond U.S. EPA Method 8330.

Superior Performance for Explosives Analysis

  • Reproducible performance
  • Simple isocratic elution conditions
  • Unique selectivities for separating other nitroaromatic molecules
  • Rugged columns with good lot-to-lot reproducibility
About the Family of Acclaim Specialty HPLC Columns
  • Developed, manufactured and tested to meet the needs of specific applications
  • Columns provide superior resolution with ease of use
  • Use-tested to guarantee consistent separations
  • Ideal selectivity for separating specific target analytes
  • Excellent peak shapes
  • Performance tested to ensure high quality and reliability